{"id":24,"date":"2017-04-18T13:49:00","date_gmt":"2017-04-18T04:49:00","guid":{"rendered":"http:\/\/www.ota.ynu.ac.jp\/index.html\/?page_id=24"},"modified":"2018-02-15T09:10:48","modified_gmt":"2018-02-15T00:10:48","slug":"research","status":"publish","type":"page","link":"http:\/\/www.ota.ynu.ac.jp\/index.html\/english\/research\/","title":{"rendered":"Research"},"content":{"rendered":"<div class=\"section clearfix\">\n<h3>Concept<\/h3>\n<div class=\"left w48 pr20 pb10 sp_reset\"><img decoding=\"async\" src=\"http:\/\/www.ota.ynu.ac.jp\/index.html\/wp-content\/uploads\/researchImg1.jpg\" alt=\"\" \/><\/div>\n<p>Research in the Ota laboratory focuses on development of sensors and systems based on advanced fabrication processes using soft materials such as polymers and hydrogels. We study mainly three areas: new fabrication processes for polymers using adhesion processing; next-generation sensors for healthcare and biotechnology; and next-generation systems integrating these sensors and circuits. Projects are based on mechanical engineering, but at the same time, they need a wide range of knowledge and techniques from chemistry, molecular biology, and electrical engineering. We propose devices and systems enabling new functionalities and properties merging mechanical engineering with these areas.<\/p>\n<p>We invite you to read about our development projects in the following. For more information, feel free to contact us.<\/p>\n<\/div>\n<div class=\"section clearfix\">\n<h4>Development of stretchable sensors using liquid metals<\/h4>\n<div class=\"section\">We are developing stretchable sensors using liquid metals (e.g., eutectic gallium-indium) and micro-fabrication techniques. One of the many applications using flexible sensors is as wearable devices. The near future will see a greater demand for stretchability of wearable devices to allow deformation of the body to be followed more freely and closely and for users to feel less discomfort. We are developing stretchable sensors using liquid metals and rubber materials. We have realized liquid metal-based sensors for pressure, temperature, humidity, and gas concentration, and will expand this technology by making other types of sensors.<\/div>\n<div class=\"imgBox clearfix\">\n<div class=\"left w48\"><img decoding=\"async\" src=\"http:\/\/www.ota.ynu.ac.jp\/index.html\/wp-content\/uploads\/researchImg2.jpg\" alt=\"\" \/><\/div>\n<div class=\"right w48\"><img decoding=\"async\" src=\"http:\/\/www.ota.ynu.ac.jp\/index.html\/wp-content\/uploads\/researchImg3.jpg\" alt=\"\" \/><\/div>\n<\/div>\n<p>Highly deformable pressure sensor (left) and wearable device (right), both using eutectic Ga-In liquid metal<\/p>\n<blockquote>\n<h5 class=\"title\">References<\/h5>\n<p>H. Ota, K. Chen et al. Nature Communication (2014)<\/p>\n<p>Y. Gao*, H. Ota* et al. Advanced Materials (2017)<br \/>\n*Equal contribution<\/p><\/blockquote>\n<\/div>\n<div class=\"section clearfix\">\n<h4>Development of healthcare and medical smart devices based on 3D printing and liquid metal sensors<\/h4>\n<div class=\"section\">We are developing next-generation smart devices for healthcare and medical applications using 3D circuits, which are fabricated by 3D printing of flexible rubber-like materials and liquid metals. These smart devices can monitor bio-markers like heartbeat, pulse, and body temperature continuously by connecting with smart phones. We have realized a smart glove with a resistive heater and a smart wearable, ear device\u2014we call it an earable device\u2014for real-time measurement of deep body temperatures based on this technology. We are contributing to healthier lives by developing these healthcare and medical smart devices.<\/div>\n<div class=\"imgBox clearfix\">\n<div class=\"left w48\"><img decoding=\"async\" src=\"http:\/\/www.ota.ynu.ac.jp\/index.html\/wp-content\/uploads\/researchImg4.jpg\" alt=\"\" \/><\/div>\n<div class=\"right w48\"><img decoding=\"async\" src=\"http:\/\/www.ota.ynu.ac.jp\/index.html\/wp-content\/uploads\/researchImg5.jpg\" alt=\"\" \/><\/div>\n<\/div>\n<p>3D printed circuit of rubber and liquid metal (left) and the\u30003D printed earable smart device for real-time measurement of deep body temperatures (right)<\/p>\n<blockquote>\n<h5 class=\"title\">References<\/h5>\n<p>H. Ota et al. Advanced Materials Technologies (2016)<\/p>\n<p>H. Ota et al. ACS Sensors (2017)<\/p><\/blockquote>\n<\/div>\n<div class=\"section clearfix\">\n<h4>Development of new fabrication processes for smart devices based on printing<\/h4>\n<div class=\"imgBox clearfix\">\n<div class=\"left w50 font16\">We are developing new fabrication processes for devices composed of soft materials, which are based on such printing processes as screen printing, inkjet printing, and roll-to-roll (R2R) printing. These fabrications assemble devices by patterning conductive liquid materials like liquid metals and carbon nanotubes. Our goal is development of a printing process having the capability for high resolution patterning, which is optimized by the four fundamental forces in mechanics.<\/div>\n<div class=\"right w45\"><img decoding=\"async\" src=\"http:\/\/www.ota.ynu.ac.jp\/index.html\/wp-content\/uploads\/researchImg6.jpg\" alt=\"\" \/><br \/>\nInkjet printing process for making smart devices<\/div>\n<\/div>\n<blockquote>\n<h5 class=\"title\">References<\/h5>\n<p>D. Kiriya et al. Journal of the American Chemical Society (2014)<\/p><\/blockquote>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Concept Research in the Ota laboratory focuses on development of sensors and systems based on advanced fabrica&#8230;\u8a73\u3057\u304f\u306f\u30b3\u30c1\u30e9<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":2,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"http:\/\/www.ota.ynu.ac.jp\/index.html\/english\/wp-json\/wp\/v2\/pages\/24"}],"collection":[{"href":"http:\/\/www.ota.ynu.ac.jp\/index.html\/english\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"http:\/\/www.ota.ynu.ac.jp\/index.html\/english\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"http:\/\/www.ota.ynu.ac.jp\/index.html\/english\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/www.ota.ynu.ac.jp\/index.html\/english\/wp-json\/wp\/v2\/comments?post=24"}],"version-history":[{"count":1,"href":"http:\/\/www.ota.ynu.ac.jp\/index.html\/english\/wp-json\/wp\/v2\/pages\/24\/revisions"}],"predecessor-version":[{"id":477,"href":"http:\/\/www.ota.ynu.ac.jp\/index.html\/english\/wp-json\/wp\/v2\/pages\/24\/revisions\/477"}],"wp:attachment":[{"href":"http:\/\/www.ota.ynu.ac.jp\/index.html\/english\/wp-json\/wp\/v2\/media?parent=24"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}